19 model(s) found.


178 download(s)
9. Variable resistance by Powersys
Variable Resistance
Type: Power
Input: R : Resistance value
Output: -
Parameters: -
149 download(s)
10. Frequency measure model by Capsim
This model helps you to measure the frequency of an electrical network. You can then evaluate the evolution of the frequency in an electrical network during a load change and use this frequency for a control loop for example.
Type: Other
Input: Phase A, B, C
Output: Frequency value
Parameters: Un : Nominal voltage , Fn : Nominal frequency
209 download(s)
11. Active and Reactive Power measure by Capsim
This model can measure the active and reactive power of a 3 phase network. The two measrure are available as an input and users can use them for a control circuit.
Type: Other
Input: Phase A, B, C
Output: Phase a, b, c
Parameters: Un : Nominal voltage , fn : Nominal frequency
134 download(s)
12. Voltage RMS measure by Capsim
This block Measure the RMS value of a voltage of a 3 phase electrical network. The output can be used in a control circuit.
Type: Other
Input: Phase A, B, C
Output: Rms value
Parameters: Un : Initial Voltage
227 download(s)
13. Voltage and Frequency variable Source by Capsim
This is a 3-phase Volage Source where you have a variable voltage and a variable frequency
Type: Sources
Input: U : Voltage reference
Output: Phase A, B, C
Parameters: -
142 download(s)
14. Electrical Load by Capsim
Electrical Load that you parameter by using the Active and Reactive Power
Type: Power
Input: Phase A, B, C
Output: -
Parameters: Pn : Active Power , Un : Nominal voltage , Fn : Nominal frequency , Cos φ : Power factor
122 download(s)
15. Variable Electrical Load by Capsim
Electrical load with two inputs : the Active Power and the Reactive Power
Type: Power
Input: Phase A, B, C
Output: -
Parameters: Un : Initial voltage value , Fn : Initial frequency value , ΔU : Votage evolution
130 download(s)
16. Saturable Transformer by Capsim
3-Phase transformer with saturation This model works only for balanced operation.
Type: Power
Input: Phase A, B, C
Output: Phase a, b, c
Parameters: F: Nominal frequency , Sn : Nominal apparent power , U1n : Primary Voltage , U2n : Secondary voltage , Po : No Load Loss[W] , Ucc : Short-circuit Voltage for I2cc=I2n [%] , Pcc : Short-circuit Power
127 download(s)
17. Passive Filter by Capsim
Passive Filter
Type: Power
Input: Phase A, B, C
Output: -
Parameters: Un : Nominal Voltage , f : Nominal frequency , Fa : Filter Frequency , Qvar : reactive power of the filter , Q : Quality factor of the filter
103 download(s)
18. Passive Filter by Capsim
Passive Filter with RLC Parameters to enter
Type: Power
Input: Phase A, B, C
Output: -
Parameters: R: Resistance of the filter , L : Inductance of the filter , C: Capacitor of the filter
125 download(s)
19. Variable Inductance by Capsim
Variable Inductance
Type: Power
Input: L : Inductance Value
Output: -
Parameters: -
112 download(s)
20. Variable 3-phase Transformer by Capsim - www.capsimulation.com
Variable 3-phase Transformer This model works only for balanced operation.
Type: Power
Input: Phase A, B, C
Output: Phase a, b, c
Parameters: Rp_(primary) : primary side resistance , Rs_(secondary) : secondary side resistance , Lp_(pri_leakage) : primray side leakage inductance , Ls_(sec_leakage) : secondary side leakage inductance , Lm(magnetizing) : Magnetizing inductance
102 download(s)
21. Synchro Coupler by Capsim
Synchro coupler
Type: Power
Input: Phase A, B, C
Output: Phase a, b, c
Parameters: f: frequency , Un : Nominal rms voltage (between two phases) , Freq_dif_max : maximal difference of frequency to close the switch , Angle max : maximal phase difference to close the switch , Voltage_dif_max : Maximal voltage difference to close the switch
129 download(s)
22. Cable by Capsim
3-Phase Cable
Type: Power
Input: Phase A, B, C
Output: Phase a, b, c
Parameters: f : frequency , Rd : linear positive sequence resistance [Ohm/km] , Ro : linear zero sequence resistance [Ohm/km] , Xd : linear positive sequence reactance [Ohm/km] , Xo : linear zero sequence reactance [Ohm/km] , L : length of the cable [m]
107 download(s)
23. Pasive Filter shunt by Capsim
Pasive Filter shunt
Type: Power
Input: Phase A, B, C
Output: -
Parameters: Un : Nominal Voltage , Fn : Nominal Frequency , Fa : Frequency of the filter , Qvar : reactive power given to the fundamental
123 download(s)
24. Mechanical Load by Capsim
Mechanical Load
Type: Power
Input: Mechanical shaft
Output: -
Parameters: Cte_w : Torque constant, in N*m , K_w : Coefficient for the linear term , K_w2 : Coefficient for the square term , K_w3 : Coefficient for the cubic term , W_nom : Nominal speed [Rad/s] , Cnom : Nominal torque [Nm] , Inertie : Moment of inertia J, in kg*m*m , Wo : Initial mechanical speed [rad/s]
102 download(s)
25. Mechanical Link by Capsim
Mechanical Link
Type: Power
Input: -
Output: -
Parameters: Stiffness [N.m/rad] , Damping [N.m.s/rad] , init_load : Initial Load , Cnom : Nominal Torque [N.m]
166 download(s)
28. indirect current control rectifier by Lou
2 level pwm rectifier with indirect current control
Type: Control
Input: Vdc , power factor
Output: Vdc
Parameters: L,C filter , , AC voltage, , power factor
132 download(s)
29. Model of IC 555 by Francesc Delis
Model for PSIM of the integrated circuit 555.
Type: Control
Input: GND, TRIGGER, RESET, CONTROL VOLTAGE, THRESHOLD, DISCHARGE, Vcc
Output: OUT
Parameters: -